Floor Plan:
1. Room partitions are made up of gypsum or hardiflex boards, metal tracks and studs. Sound proofing materials also applied here. ( egg trays, styrofoams, or any conventional sound proofing materials.
2. Restroom wall is made up of reinforced concrete filled hollow blocks, water proofing membrane, tile adhesive and ceramic tiles on the surface.
Architectural:
The audio/visual system will support DVD players, android boxes, and desktop media platforms.
Exterior Perspective
Reception Area
The Aisle of movie rooms
Interior of each movie room
Electrical:
Single Wire Diagram
Power Layout
The lighting on each room can use a conventional pin light and led light bulb combination or led panel downlights. The reception area light bulbs can be pin type, panel down light, or drop lights.
Lighting Layout
CKT
|
LOAD
|
PHASE
|
OUTLET RATING
|
NO. OF OUTLET
|
VA
|
VOLTS
|
WIRE
|
CB
|
CND
|
1
|
LED BULB (X16)
|
LINE 1
|
15A/240V
|
12
|
6W (X16)
|
240V
|
THHN 3.5mm2
|
15A
|
½
|
EXHAUST FAN
|
20W
|
240V
|
THHN 3.5mm2
|
½
| |||||
EMERGENCY LIGHT
|
30W (X2)
|
240V
|
THHN 3.5mm2
|
½
| |||||
LED SIGNAGE
|
100W MAX
|
240V
|
THHN 3.5mm2
|
½
| |||||
2
|
PROJECTOR (X8)
|
LINE 1
|
15A/240V
|
8
|
257W (X8)
|
240V
|
THHN 3.5mm2
|
20A
|
½
|
STAND FAN
|
1
|
60W
|
240V
|
THHN 3.5mm2
|
½
| ||||
3
|
AUDIO AMPLIFIER (X8)
|
LINE 2
|
15A/240V
|
8
|
350W (X8)
|
240V
|
THHN 3.5mm2
|
20A
|
½
|
4
|
DVD PLAYER (X8)
|
LINE 3
|
15A/240V
|
8
|
15W (X8)
|
240V
|
THHN 3.5mm2
|
20A
|
½
|
DESKTOP PC
|
1
|
500W
|
240V
|
THHN 3.5mm2
|
½
| ||||
DVR/CCTV
|
1
|
35W
|
240V
|
THHN 3.5mm2
|
½
| ||||
AV SELECTOR
|
1
|
15W
|
240V
|
THHN 3.5mm2
|
½
| ||||
5
|
REFRIGERATOR
|
LINE 3
|
20A/240V
|
1
|
400W
|
240V
|
THHN 3.5mm2
|
20A
|
½
|
6
|
AIR CONDITIONER
|
LINE 1
|
20A/240V
|
1
|
900W MAX
|
240V
|
THHN 5.5mm2
|
30A
|
½
|
7
|
AIR CONDITIONER
|
LINE 2
|
20A/240V
|
1
|
900W MAX
|
240V
|
THHN 5.5mm2
|
30A
|
½
|
8
|
AIR CONDITIONER
|
LINE 3
|
20A/240V
|
1
|
900W MAX
|
240V
|
THHN 5.5mm2
|
30A
|
½
|
9
|
AIR CONDITIONER
|
LINE 1
|
20A/240V
|
1
|
900W MAX
|
240V
|
THHN 5.5mm2
|
30A
|
½
|
10
|
AIR CONDITIONER
|
LINE 2
|
20A/240V
|
1
|
900W MAX
|
240V
|
THHN 5.5mm2
|
30A
|
½
|
11
|
AIR CONDITIONER
|
LINE 3
|
20A/240V
|
1
|
900W MAX
|
240V
|
THHN 5.5mm2
|
30A
|
½
|
12
|
AIR CONDITIONER
|
LINE 1
|
20A/240V
|
1
|
900W MAX
|
240V
|
THHN 5.5mm2
|
30A
|
½
|
13
|
AIR CONDITIONER
|
LINE 2
|
20A/240V
|
1
|
900W MAX
|
240V
|
THHN 5.5mm2
|
30A
|
½
|
Schedule of Loads
ELECTRICAL GENERAL NOTES
1.0 GENERAL LIGHTING
1.1 CIRCUIT – The entire lighting circuit is connected to Line 1 (Color code: Red) and Neutral (Color code: White) plus Ground (Color code: Green) 230V of the power source with a circuit breaker rated a 15A. Wall switches and receptacles are rated at 15A/240V. The wires in this circuit are all THHHN 3.5mm2. Junction and utility boxes are all metal type. Conduit pipes and flexible conduits are all PVC s40 type.
1.2 LOAD- Led bulbs of E27 socket type, exhaust fan, emergency lights and a led store front signage are connected in the circuit. The total power output of loads does not exceed the maximum ampacity of the circuit.
2.0 GENERAL POWER
2.1 CIRCUIT 1- The circuit is connected to Line 1 (Color code: Red) and Neutral (Color code: White) plus Ground (Color code: Green) 230V of the power source. Wall receptacles are rated at 15A/240V. All wires in the circuit are THHN 3.5mm2. Utility and junction boxes are all metal type. Conduit pipes are all PVC s40 type. The circuit breaker in this circuit is rated 20A in the panel board.
2.1.1 LOAD-Ceiling-mounted graphics projectors in every movie room with wall receptacles at 15A/240V located near on each unit. A convenience wall receptacle located near reception area which possible load is a 60 watt stand fan. The total power output of loads does not exceed the maximum ampacity of the circuit.
2.2 CIRCUIT 2- The circuit is connected to Line 2 (Color code: Yellow) and Neutral (Color code: White) plus ground (Color code: Green) 230V of the power source. Wall receptacles are rated at 15A/240V. All wires in the circuit are THHN 3.5mm2. Utility and junction boxes are all metal type. Conduit pipes are all PVC s40 type. The circuit breaker in this circuit is rated 20A in the panel board.
2.2.1 LOAD- Stereo amplifier systems in every movie room with wall receptacles at 15A/240V located near on each unit. The total power output of loads does not exceed the maximum ampacity of the circuit.
2.3 CIRCUIT 3- The circuit is connected to Line 3 (Color Code: Blue) and Neutral (Color code: White) plus Ground (Color code: Green) 230V of the power source. Wall receptacles are rated at 15A/240V. All wires in the circuit are THHN 3.5mm2. Utility and junction boxes are all metal type. Conduit pipes are all PVC s40 type.
2.3.1 LOAD- A desktop computer, DVD Players, DVR/CCTV box of four dome cameras, audio/video selector component, a flat screen monitor and convenience outlets. The circuit breaker in this circuit is rated 20A in the panel board.
3.0 DEDICATED CIRCUITS
3.1 CIRCUIT BREAKERS- Each refrigeration and air conditioning unit have its own dedicated circuit with a 30A circuit breaker in the panel board. In Line 1, there will be three aircon circuits. In Line 2, there will be three aircon circuits. In Line 3, there will be two aircon circuits and 1 refrigerator circuit.
4.0 SINGLE WIRE DIAGRAM SYMBOLS
POWER SOURCE: 3 PHASE LINE TO NEUTRAL 230V PLUS GROUND COLOR CODE: LINE 1- RED, LINE 2- YELLOW, LINE 3- BLUE, NEUTRAL- WHITE, GROUND- GREEN
Note that toilet bowl does not need an additional p-trap piping because toilet bowls nowadays come with their own p-trap.
Isometric Diagram
Sanitary/Water Layout
Connection Details in 3D
Lavatory
Rest Room Flooring
Rest Room Dimension
GENERAL SPECIFICATION SANITARY/WATER WORKS
DESCRIPTION
|
MATERIAL
|
BRAND/MANUFATURER
|
1.0 CONDENSATE DRAINAGE
VERTICAL/LATERAL
|
POLYVINYL CHLORIDE (PVC SERIES 1000) 2’
|
ATLANTA
|
2.0 SANITARY DRAINAGE
| ||
2.1 LAVATORY
|
POLYVINYL CHLORIDE (PVC SERIES 1000) 2’
|
ATLANTA
|
2.2 FLOOR DRAIN
|
POLYVINYL CHLORIDE (PVC SERIES 1000) 3’
|
ATLANTA
|
2.3 MAIN DRAINAGE
|
POLYVINYL CHLORIDE (PVC SERIES 1000) 4’
|
ATLANTA
|
3.0 SEWERAGE
|
POLYVINYL CHLORIDE (PVC SERIES 1000) 4’
|
ATLANTA
|
4.0 POTABLE WATER CONNECTION
| ||
4.1 PIPE/TEE/ELBOW
|
POLYPROPYLENE RANDOM (PPR 20mm)
|
NELTEX
|
4.2 ANGLE VALVE/WATER CLOSET
|
TRIVALVE ½ X ½ METALLIC
|
SHARK
|
4.3 ANGLE VALVE/LAVATORY
|
ANGLE VALVE ½ X ½ METALLIC
|
SHARK
|
4.4 GATE VALVE
|
GATE VALVE ½ BRASS
|
CRESTON
|
4.5 FLEXIBLE HOSES
|
½ X ½ X 12’ PLASTIC
|
LOTUS
|
4.6 LAVATORY FAUCET
|
½ CHROME PLATED ALLOY CAST
|
SHARK
|
5.0 WATER CLOSET/BOWL
|
TOILET BOWL (2 PIECE) PORCELAIN
|
HCG
|
6.0 LAVATORY SINK/PEDESTAL
|
LAVATORY/PEDESTAL SET PORCELAIN
|
HCG
|
7.0 CEMENT
|
PVC CEMENT
|
ATLANTA
|
8.0 PIPE SEALING
|
EPOXY A/B CONSTRUCTION
|
PIONEER
|
Mechanical:
Airconditioning setup can be done also by using standing floor type aircon unit using ducts.
Aircon Layout
Sprinkler and Fire Alarm Layout
Aircon Unit Water Condensate Drainage Insulation Details
Note: Instead of G.I pipe, B.I. pipe is commonly used or the standard piping materials in fire protection.
As of April 10, 2019, the space is currently available for leasing. Please inquire at Parkmall Admin. The rent of commercial space was 200 to 230 Php/ square meter/ a month in the contract.
By the way and to be honest, I am not an engineer nor an architect. I am only a skilled laborer as freelance electrician and deals with small scale renovation projects. I have some experience in making partitions, plumbing, cctv installation, audio/visual setup or networking, solar panel installation both off-grid and grid-tied in small scale. I am not also very fluent in English, the grammar and technical writing skills.
By the way and to be honest, I am not an engineer nor an architect. I am only a skilled laborer as freelance electrician and deals with small scale renovation projects. I have some experience in making partitions, plumbing, cctv installation, audio/visual setup or networking, solar panel installation both off-grid and grid-tied in small scale. I am not also very fluent in English, the grammar and technical writing skills.